Specifications
Product Features
- Extremely low headloss
- Suitable for most piping materials and sizes
- Simple installation
- Long lifetime
- Maintenance-free
- No mechanical parts
- Self-cleaning
Applications
- Backflow protection
- Flushing
- Odor Control
Our range of EVR-MwStop valves can be installed in various ways in any position from horizontal to vertical, full functionality is given.
Options
Standard – EVR-MwStop
For Gradients > 2%
To ensure the full functionality of the EVR-MwStop, a minimum gradient of 2% is required in the standard version. The EPDM membrane of the EVR-MwStop opens up at a certain water pressure (water flow) and closes if this pressure falls below the normal level. The EVR-MwStop remains closed until the inlet water backlog reaches the trigger point. At the trigger point, the membrane snaps open, creating the controlled flushing process.
Soft – EVR-MwStop
For Low Gradients
For installation in pipes with a gradient of less than 2% (minimum 1% is required) the membrane of the EVR-MwStop consists of a more flexible material. This ensures that even in these situations, the flushing process removes the waste water, inclusive of residual deposits.